INTERNAL VISUAL per MIL-STD-883, Method 2017 and 2032
STABILIZATION BAKE (Prior to Seal) per MIL-STD-883, Method
1008, Condition C (150ºC)
TEMPERATURE CYCLING per MIL-STD-883, Method 1010, Condition B
(-55ºC to 125ºC)
CONSTANT ACCELERATION per MIL-STD-883, Method 2001, Condition
A (Y1 Axis only, 5000g)
FINE LEAK per MIL-STD-883, Method 1014, Condition A
GROSS LEAK per MIL-STD-883, Method 1014, Condition C
PRE BURN-IN Electrical Test, Output Frequency and Waveform at
nominal supply voltage, Specified Load, +23ºC
±1ºC (OPTIONAL)
BURN-IN (Load) Energized oscillator, with nominal supply
voltage and burn-in load, is tested at 125ºC
for 160 hours min.
FINAL ELECTRICAL TEST: Input Current Power, Output Frequency,
Output Waveform, and Output Voltage Power are tested
GROUP A
ELECTRICAL TEST: Supply Voltage, Input Current, Output
Waveform, Output Voltage Power, Rise and Fall Times, Duty Cycle, and Start-Up
Time (as required)
FREQUENCY-TEMPERATURE STABILITY: Initial Accuracy at
Reference Temperature, Initial Frequency-Temperature Accuracy and
Frequency-Temperature Tolerance
FREQUENCY-VOLTAGE TOLERANCE: Output Frequency is measured
when oscillator supply voltage is adjusted to its specified nominal value up to
its maximum / minimum values
OVERVOLTAGE SURVIVABILITY: Overvoltage of 20% above the
maximum specified
VISUAL AND MECHANICAL: Verify Material, Design,
Construction, Workmanship, Physical Dimensions, and Marking per MIL-PRF-55310
SOLDERABILITY TEST per MIL-STD-202, Method 208
GROUP B
AGING TEST: Oscillator is energized in oven for a
continuous period of 30 days at 70ºC ±3ºC. The Output frequency is measured
within an interval of 72 hours maximum per MIL-PRF-55310
GROUP C
VIBRATION (Sinusoidal) non-operating per MIL-STD-202, Method 204,
per MIL-PRF-55310
SHOCK (Specified Pulse) per MIL-STD-202, Method 213
(non-operating)
THERMAL SHOCK per MIL-STD-202, Method 107
AMBIENT PRESSURE (operating and non-operating) per MIL-STD-202,
Method 105, and MIL-PRF-55310
STORAGE TEMPERATURE per MIL-PRF-55310
RESISTANCE TO SOLDERING HEAT per MIL-STD-202, Method 210
MOISTURE RESISTANCE per MIL-STD-202, Method 106
SALT SPRAY per MIL-STD-883, Method 1009
TERMINAL STRENGTH per MIL-STD-202, Method 211
RESISTANCE TO SOLVENTS per MIL-STD-202, Method 215